When data centers need storage expansion that delivers low power and high capacity with high-availability, they rely on the HGST 4U60 Storage Enclosure. This high-density, scalable, and cost-effective design includes 60 Ultrastar® 3.5-inch drive modules in a 4U enclosure, supports up to 8 hosts with SAS 12Gb/s performance, and delivers enterprise-class serviceability with hot-swappable components.
This integrated platform is qualified, tested and certified to support a broad range of HGST HDDs. It’s available with SAS drives for high-availability (HA) applications, with SATA drives for cost-optimized applications, and can be configured with up to twelve (12) 800GB SSDs to create separate performance tiers within the platform.
Read the HGST 4U60 Performance and Compatibility Tests by RAIDIX Testing Lab
High Density – Up to 720TB* in a 4U enclosure
Scalable – Supports 8 hosts per platform
Enterprise-class Serviceability – Hot-swappable components, cable management arm
*720TB capacity is only available with the 4U60G2 platform. Availability varies by country.
Model |
4U60G2 | 4U60 |
General |
||
Host Connections |
8 x 12Gbps SAS (4 per IOM) |
4 x 12GBps SAS (2 per IOM) |
Capacity / Physical Size |
||
Capacity (minimum) |
144TB with 6TB drive modules |
96TB with 4TB drive modules |
Capacity (maximum) |
720TB with 12TB drive modules |
600TB with 10TB drive modules |
Dimensions (Enclosure) |
174.8mm x 424mm x 871.2mm / 6.88in. x 16.69in. x 34.3in. |
174.8mm x 424mm x 871.2mm / 6.88in. x 16.69in. x 34.3in. |
Dimensions (Enclosure w/ CMAs) |
174.8mm x 424mm x 1110mm / 6.88in. x 16.69in. x 43.7in. |
174.8mm x 424mm x 983mm / 6.88in. x 16.69in. x 38.7in. |
Weight |
89.81 kg (198 lbs.) – fully configured with 60 helium drive modules 93.71 kg (208 lbs) – fully configured with 60 air drive modules |
89.81 kg (198 lbs.) – fully configured with 60 helium drive modules 93.71 kg (208 lbs) – fully configured with 60 air drive modules |
Power and Cooling: Operating |
||
Power Supply |
Two 1,650W PSUs, hot swap and redundant |
Two 1,650W PSUs, hot swap and redundant |
Input Voltage |
200-240VAC auto-ranging, 47Hz-63Hz input (high line power only) |
200-240VAC auto-ranging, 47Hz-63Hz input (high line power only) |
Cooling Fans |
N+1 redundant fans (fans integrated into PSU) |
N+1 redundant fans (fans integrated into PSU) |
Environmental (operating) |
||
Temperature Range |
10° to 35°C |
10° to 35°C |
Humidity |
8% to 80% (non-condensing) |
8% to 80% (non-condensing) |
Shock |
3.5g 6ms Pulse vertical shock |
3.5g 6ms Pulse vertical shock |
Vibration |
Random 0.25 Grms, 5-10Hz, 0.05 g sine wave sweep, 10-300Hz |
Random 0.25 Grms, 5-10Hz, 0.05 g sine wave sweep, 10-300Hz |
Acoustics |
<7.5dB LwA @ 23ºC |
<7.5dB LwA @ 23ºC |
Environmental (non-operating) |
||
Temperature Range |
-30° to 60°C |
-30° to 60°C |
Humidity |
8% to 80% (non-condensing) |
8% to 80% (non-condensing) |
Shock |
8g 6ms Trapezoidal |
8g 6ms Trapezoidal |
Vibration |
Random 0.6 Grms 10-300Hz |
Random 0.6 Grms 10-300Hz |
Resources |
||
HGST 4U60 JBOD Diagram | ||
4U60 Storage Enclosure Compatibility Guide |
KEY FEATURESUp to 60 integrated Ultrastar® drive modules
Hybrid capability: can be configured with SSDs to create separate performance tiers within the platform Available with SAS drives for HA application or with SATA drives for cost-optimized applications Available with 512e or 4Kn sector size (by part number) Supports up to 4 storage enclosures for daisy-chaining* Host connectivity:
Fully compliant with 12Gb/s SAS 3 interconnect Hot-swappable components: two power supplies with integrated fans, drive modules, and IO Modules Cable Management Arm (CMA) eliminates tangled cables during servicing of hot-swappable CRUs SCSI Enclosure Services (SES-3) Microsoft certified for Windows Server 2012, 2012R2 5-year limited warranty *Only available with the 4U60 storage platform. |